Chest tubes
|
-
Anterior tube drains mostly air from
pleural
-
Posterior
tube drains mostly fluid from pleural space
-
Removal of fluid and air from pleural space
is necessary to reestablish negative intrapleural pressure
|
-
Thoracotomy
-
Open heart surgery
-
Spontaneous
pneumothorax
-
Traumatic
pneumothorax
|
-
See Key Points for each
of the three entries under Drainage system, below
-
Sterile technique is used when changing
dressings around the tube insertions
-
Fowler’s position to facilitate air and fluid
removal
-
Cough, deep breathe qlh; splint chest;
medicate for pain
-
Manage pain carefully in order not to
depress respirations
-
Prepare for removal when there is little or
no drainage, air leak disappears, or fluctuations stop in water seal; have suture set,
air-occlusive dressing, and sturdy elastic tape ready; medicate for pain before removal; monitor
breathing after removal (breath sounds, rate, chest pain)
|
Drainage system
-
drainage compartment
|
Collects drainage
|
|
-
Mark level in bottle each shift to keep
accurate record - nor routinely emptied; replaced when full
-
Never raise container above the level of
the chest; otherwise backflow will occur
|
-
water-seal chamber
|
Water seal prevents flow of atmospheric air into pleural space; essential to prevent
recollapse of the lung
|
|
-
Air bubbles from postoperative residual
air will continue for 24-48 hr
-
Persistent large amounts of air bubbles in this compartment indicate an air leak between the alveoli
and the pleural space
-
Clamp tube(s) only to verify a leak; replace a broken,
cracked, or full drainage unit; or verify readiness of patient for tube removal; not necessary
to clamp when ambulating if water seal intact
-
If tube becomes disconnected, place tubing end in sterile water or saline; if
dislodged from chest, seal insertion site immediately on expiration if possible; use
sterile air-occlusive dressing
-
If air leak is present, clamping the tube for very long (more than 10 sec) may
cause a tension pneumothorax
-
Fluctuation of the fluid level in this bottle is expected (when the suction is turned off)
because respiration changes the pleural pressure: if there is no fluctuation of the fluid in the tube of
this bottle (when the suction is turned off), either the lung is fully expanded or the tube is
blocked by kinking or by a clot
-
Although not routinely used, milking (gently squeezing) the tubes, if ordered,
will prevent blockage from clots Or debris; otherwise gravity drainage is sufficient to maintain
patency
-
Drainage of more than 100 mL in 1 hr should be reported to physician
|
-
suction control - connected to wall suction
|
Level of the column of water (i.e., 15-20 cm) is used to control the amount of suction
applied to the chest - if the water evaporates to only 10 cm depth, this will be the maximum suction generated by the wall suction
|
|
-
Air should continuously
bubble through this compartment when the suction is on; the bubbles
are from the atmosphere - not the patient; when the wall suction is turned higher, the bubbling
will increase, but the increased pulling of air is from the atmosphere and nor from the pleural
space
-
Because the level of H,O determines the maximum negative pressure that can be
obtained, make sure the water does nor evaporate - keep filling the bottle to keep the ordered
level; if there is no bubbling of air through this container, the wall suction is too low
|
|
Heimlich flutter valve
|
- Has a one-way valve so fluids and air can drain out of the pleural space but cannot flow back.
-
Eliminates the need for a water seal - no danger when tube is unclamped below the valve
|
Same as for other chest tubes
|
-
Can be connected to suction of ordered
-
Sometimes can just drain into portable bag sop patient is more mobile
|
|
Tracheostomy tube
|
-
1. Maintains patent airway and promotes better
O2 - COi exchange
-
Makes removal of secreations by suctioning easier
-
3. Cuff on trach is necessary if need airtight fit for assisted
ventilation
|
-
Acute respirator distress due to poor ventilation
-
Severe burns of head and neck
-
Laryngectomy (trach is permanent)
|
-
Use oxygen before and after each suctioning
-
Humidify oxygen
-
Sterile technique in suctioning; clean technique at home
- Cleanse inner cannula as needed - only leave out 5-10 min
-
Hemostat handy if outer cannula is expelled - have obturator
taped to bed and another trach set handy
-
Cuff must be deflated periodically to prevent necrosis of mucosa, unless low-pressure cuff used
|
|
Penrose drain
|
Soft collapsible latex rubber drain inserted to drain serosanguineous fluid from a
surgical site; usually brought out to the skin via a stab wound
|
Bowel resection
|
-
Expect drainage to progress from scrosanguineous to more serous
-
Sterile technique when changing dressing—do often
-
Physician will advance tube a little each day
|
|
Nasogastric (NG) tubes
|
|
Levin tube and small-bore feeding tubes
|
-
Inserted into stomach to decompress by removing gastric contents and air-prevents any
buildup of gastric secretions, which are
-
Used when stomach must be washed out
-
Used for feedings when patient is unable to swallow (gavage)
|
-
Any abdominal or other surgery after which peristalis is absent for a few days
-
Overdoses
-
Gastrointestinal
hemorrage
-
Cancer of the esophagus
-
Early postoperative care for patient who had a laryngectomy or radial neck dissection
|
-
Connect to low intermittent suction
-
Irrigate prn with normal saline or puffs of air
-
Clean, but not sterile, procedure
-
Mouth care needed
-
Report "coffee ground" material (digested blood)
-
For overdose, stomach is pumped out as rapidly as possible
-
For hemorrhage, tepid normal saline may be used to lavage
-
Critical to make sure tube still in stomach before beginning feeding; listen for air passing into stomach, and if possible aspirate gastric contents; small-bore tubes require placement check x-ray
-
Follow feeding with some water to rinse out the tube
-
Clamp tube when ambulating
-
With larger-bore tubes, determine residuals and withhold feeding if large residuals obtained
|
|
Salem sump
|
Double-lumen tube with vent to protect gastric mucosa from trauma of suctioning
|
same as Levin tube
|
-
Irrigate vent (blue tubing) with air only
-
See Levin tube
|
|
Gastronomy tube
|
-
Inserted into stomach via abdominal wall
-
May be used for decompression
-
Used long term for feedings
|
Conditions affecting esophagus in which it is impossible to insert a nasogastric tube
|
-
Principles of tube feeings same as with Levin nasogastric tube, except no danger that tube is in trachea
-
If permanent, tube may be replaceable
|
|
Miller-Abbott tube Cantor tube
|
Longer than Levin tube - has mercury or air
in bags so tube can be used to decompress the lower intestinal tract
|
-
Small-bowel
obstrue-
-
Intussusception
-
Volvulus
|
-
Care similar to that for Levin NG tube - irrigated
-
Connected to suction, not sterile
technique
-
Orders will be written on
how to advance the tube, gently pushing tube a few inches each hour; patient
position may affect advancement of tube
-
X-rays determine the desired location of tube
|
|
T-tube
|
To drain bile from the common
bile duct until edema has subsided
|
Cholecystectomy when a common
duct exploration (CDE) or choledochostomy was also done
|
-
Bile
drainage is influenced by position of the
drainage bag
-
Clamp
tube as ordered to see if bile will flow into duodenum normally
|
|
Hemovac
|
A type of closed-wound drainage
connected to suction - used to drain a large amount of
serosanguineous drainage from under an incision
|
-
Mastectomy
-
Total hip procedures
-
Total knee procedures
|
-
May
compress unit, and have portable vacuum or connect to wall suction
-
Small
drainage tubes may get clogged - physician may irrigate these at times
|
|
Jackson-Pratt
|
-
A method of closed wound
suction drainage - indicated when tissue displacement and tissue trauma may
occur with rigid drain tubes (e.g„ Hemovac)
-
See Hemovac
|
-
Neurosurgery
-
Neck
surgery
-
Mastectomy
-
Total
knee and hip replacement
-
Abdominal surgery
-
Urological procedures
|
-
Empty reservoir when full, to
prevent loss of wound drainage and back-contamination
-
See Hemovac.
|
|
Three-way Foley
|
To provide avenues for constant irrigation and constant drainage
of the urinary bladder
|
-
Transurethral resection (TUR)
-
Bladder infections
|
-
Watch for blocking by clots - causes bladder spasms
-
Irrigant solution often hasantibiotic added to
normal saline or sterile water
-
Sterile water rather than normal saline may be
used for lysis of clots
|
|
Suprapubic catheter
|
To drain bladder via an opening
through the abdominal wall above the pubic bone
|
Suprapubic
prostatec-
|
May have orders
to irrigate pm or continuously
|
|
Ureteral catheter
|
To drain urine from the pelvis of
one kidney, or for splinting ureter
|
-
Cystoscopy for
diagnostic workups
-
Ureteral surgery
-
Pyelotomy
|
-
Never clamp the tube - pelvis of kidney only holds
4-8 mL
-
Use